Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Arq. bras. oftalmol ; 83(2): 127-131, Mar.-Apr. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088964

ABSTRACT

ABSTRACT Purpose: Inferior eyelid laxity is classically evaluated using "snap-back" and "distraction" tests. This study aimed to assess the reproducibility of the technique used to indirectly quantify the horizontal tension in the lower eyelids using digital image processing. Methods: This longitudinal study was conducted to assess the reproducibility of a new technique that quantifies the horizontal tension in the lower eyelid. The study was conducted at the Hospital das Clínicas of Porto Alegre. The protocol was established by two trained ophthalmologist examiners, allowing intra- and interobserver agreement analyses. Image acquisition was done in two stages: the first image was captured with the eyelid in primary gaze position and the second with the eyelid in traction position. All images and measurements were processed using Image J 1.33m software from the National Institute of Health. The Bland-Altman method, intraclass correlation coefficients, concordance correlation coefficients, and technical measurement error were used to evaluate reproducibility. Results: The study participants comprised healthy individuals with no ophthalmologic pathologies. The measurements obtained in the neutral position showed a slightly higher agreement than those obtained in the traction position. The mean difference between the measurements performed in the traction position was 0.028 ± 0.7 mm and 0.014 ± 0.9 mm in the intra- and interobserver analyses, respectively. The Bland-Altman method demonstrated adequate confidence limits for both measurements. Correlation coefficients for measurements varied between 0.87 [95% confidence interval (CI) 0.68-0.95] and 0.91 (95% CI 0.77-0.97) in the neutral position and between 0.72 (95% CI 0.37-0.89) and 0.76 (95% CI 0.4-0.91) in the traction position. Conclusion: A high intra- and interobserver concordance was observed in the studied method to quantify lower eyelid tension. The proposed method is simple and easily reproducible, and to the best our knowledge, this is the first method that quantifies lower eyelid horizontal tension on the basis of digital image processing. This modified distraction test might be useful in studies quantifying lower eyelid horizontal tension.


RESUMO Objetivo: A frouxidão palpebral inferior é avaliada classicamente por meio de testes de "snap-back" e "distraction test". O objetivo deste estudo foi avaliar a reprodutibilidade da técnica utilizada para quantificar indiretamente a tensão horizontal nas pálpebras inferiores através do processamento digital de imagens. Métodos: Este estudo longitudinal foi realizado para avaliar a reprodutibilidade de uma nova técnica que quantifica a tensão horizontal na pálpebra inferior. O estudo foi realizado no Hospital das Clínicas de Porto Alegre. O protocolo foi estabelecido por dois examinadores oftalmologistas treinados, permitindo análises de concordância intra e interavaliador. A aquisição de imagens foi feita em duas etapas: a primeira imagem foi capturada com a pálpebra na posição primária do olhar e a segunda com pálpebra tracionada. Todas as imagens e medições foram processadas usando o software Image J 1.33m do National Institute of Health. O método de Bland-Altman, os coeficientes de correlação intraclasses, os coeficientes de correlação de concordância e o erro técnico da medida foram utilizados para avaliar a reprodutibilidade. Resultados: Os participantes do estudo foram indivíduos saudáveis e sem patologias oftalmológicas. As medidas obtidas na posição neutra mostraram concordância levemente maior do que as obtidas na posição tracionada. A diferença média entre as medidas realizadas na posição tracionada foi de 0,028 ± 0,7mm e 0,014 ± 0,9mm nas análises intra e interobservadores, respectivamente. O método de Bland-Altman demonstrou limites de confiança adequados para ambas as medidas. Os coeficientes de correlação para as medidas variaram entre 0,87 [intervalo de confiança de 95% (IC) 0,68-0,95) e 0,91 (IC 95% 0,77-0,97) na posição neutra e entre 0,72 (IC 95% 0,37-0,89) e 0,76 (IC 95% 0,46-0,91) na posição tracionada. Conclusão: Observou-se elevada concordância intra e interobservador no método estudado para quantificar a tensão palpebral inferior. O método proposto é simples e facilmente reproduzível, e, do melhor modo possível, este é o primeiro método que quantifica a tensão horizontal da pálpebra inferior com base no processamento digital de imagens. Este teste de distração modificado pode ser útil em estudos que quantifiquem a tensão horizontal da pálpebra inferior.


Subject(s)
Humans , Adult , Middle Aged , Image Processing, Computer-Assisted/methods , Image Processing, Computer-Assisted/standards , Image Interpretation, Computer-Assisted/methods , Eyelid Diseases/physiopathology , Eyelid Diseases/diagnostic imaging , Reference Values , Software , Photography/methods , Observer Variation , Prospective Studies , Reproducibility of Results , Eyelids/physiopathology , Eyelids/diagnostic imaging
2.
Arq. bras. oftalmol ; 72(3): 384-386, May-June 2009. ilus
Article in English | LILACS | ID: lil-521477

ABSTRACT

A 19 year old female with pyoderma gangrenosum was referred to the oculoplastic clinic for evaluation of severe cicatricial ectropion of the right lower eyelid. Examination evidenced important scarring of lower eyelid and malar region with secondary ectropion. A full-thickness skin graft associated with a lateral tarsal strip procedure and scar tissue release was performed. The patient's corticosteroid dose was raised for the procedure, and after surgery there was no healing problem or ulcer formation in the eyelid or in the graft donor site. As pyoderma gangrenosum is associated with a pathergy phenomenon in up to 25 percent of the cases, the onset of new lesions is a relevant concern when performing surgery in these patients. In this case, the surgery was safely performed under corticosteroid immunosuppression.


Paciente do sexo feminino de 19 anos com pioderma gangrenoso foi encaminhada ao setor de Plástica Ocular para avaliação de ectrópio cicatricial grave da pálpebra inferior direita. O exame evidenciou cicatrização importante na pálpebra inferior e região malar com um ectrópio secundário. Foi realizado liberação do tecido cicatricial e um enxerto de pele total associado a "tarsal strip". A dose de corticóide da paciente foi aumentada para a realização do procedimento e não houve problemas de cicatrização ou formação de úlceras na pálpebra ou no sítio doador após a cirurgia. Como o pioderma gangrenoso é associado ao fenômeno de patergia em até 25 por cento dos casos, o surgimento de novas lesões é uma preocupação relevante ao indicar cirurgia nestes pacientes. Neste caso, a cirurgia foi realizada com segurança sob imunossupressão com corticóide.


Subject(s)
Female , Humans , Young Adult , Blepharoplasty/methods , Cicatrix/surgery , Ectropion/surgery , Pyoderma Gangrenosum/complications , Adrenal Cortex Hormones/administration & dosage , Cicatrix/etiology , Ectropion/etiology , Immunosuppressive Agents/administration & dosage , Skin Transplantation , Young Adult
3.
Arq. bras. oftalmol ; 71(6): 781-787, nov.-dez. 2008. ilus, graf, tab
Article in English | LILACS | ID: lil-503439

ABSTRACT

PURPOSE: To evaluate the long-term outcome of HLA-matched lr-CLAL for bilateral ocular surface disorders. METHODS: A retrospective, non-comparative interventional case series study of 39 eyes of 32 patients with bilateral surface disorders and clinical diagnosis of limbal stem cell deficiency who underwent HLA-matched lr-CLAL. Visual acuity (VA), ambulatory vision (> 20/200) and ocular surface stability were evaluated as main outcomes. Donor limbus was obtained from a sibling or a parent of the patient, after an appropriate Class I and II HLA match. RESULTS: One year after surgery, VA improved in 46.2 percent, ambulatory vision was achieved in 48.7 percent and a stable corneal surface was achieved in 84.6 percent of the eyes. At the final follow-up (mean, 48.7 ± 30.6 months), 66.6 percent of the eyes that had gained VA one year after surgery maintained an improved VA (p=0.28), 94.7 percent of eyes that had achieved ambulatory vision one year after surgery maintained 20/200 or better (p<0.001) and 93.9 percent still had a stable corneal surface (p=0.043) at the final follow-up. CONCLUSIONS: HLA-matched lr-CLAL can be an adequate method of treatment for bilateral ocular surface disorders, with a reasonable percentage of success of long-term results.


OBJETIVO: Avaliar os resultados em longo prazo do transplante alogênico inter vivo de limbo conjuntival para doenças bilaterais da superfície ocular com compatibilidade HLA doador-receptor. MÉTODOS: Estudo retrospectivo, não comparativo e intervencionista de 39 olhos de 32 pacientes submetidos a transplante alogênico de limbo com compatibilidade HLA e diagnóstico de deficiência límbica. Foram analisados como desfechos principais acuidade visual, visão ambulatorial (> 20/200) e estabilidade da superfície ocular. Limbo doador foi obtido de parentes do paciente após estudo de compatibilidade HLA classe I e II. RESULTADOS: Com um ano de pós-operatório, a acuidade visual melhorou em 46,2 por cento, visão ambulatorial foi atingida em 48,7 por cento e estabilidade da superfície corneana em 84,6 por cento dos pacientes. Ao final do seguimento (média, 48,7 ± 30,6 meses), 66,6 por cento dos olhos que haviam ganho acuidade visual um ano após a cirurgia mantiveram esta melhora (p=0,28), 94,7 por cento dos olhos que haviam alcançado visão ambulatorial um ano após a cirurgia mantiveram visão de 20/200 ou melhor (p<0,001) e 93,9 por cento ainda tinham superfície corneana estável (p=0,043) ao final do seguimento. CONCLUSÕES: O transplante alogênico inter vivo de limbo conjuntival com compatibilidade HLA revelou-se método adequado no tratamento de doenças bilaterais da superfície ocular, com uma porcentagem significativa de sucesso a longo-prazo.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Humans , Middle Aged , Young Adult , Corneal Diseases/surgery , Epithelium, Corneal/transplantation , Limbus Corneae/immunology , Stem Cell Transplantation , Visual Acuity/physiology , Ambulatory Care , Corneal Diseases/etiology , Corneal Diseases/immunology , Epithelium, Corneal/immunology , Epithelium, Corneal/pathology , Follow-Up Studies , Graft Rejection/immunology , Histocompatibility Testing , Kaplan-Meier Estimate , Living Donors , Retrospective Studies , Stem Cell Transplantation/methods , Transplantation, Homologous , Treatment Outcome , Young Adult
4.
Arq. bras. oftalmol ; 65(6): 651-654, nov.-dez. 2002. tab, graf
Article in Portuguese | LILACS | ID: lil-324553

ABSTRACT

Objetivo: Estudar a acuidade visual dos candidatos a condutores de veículos da cidade de Pelotas e sua associação com as características sociodemográficas dos candidatos. Métodos; Foram examinados 1.010 candidatos a condutores em um serviço médico autorizado pelo Detran. Avaliou-se a acuidade visual, com e sem correção, bem como a sua relação com a visão de cores, sexo, idade e profissão dos entrevistados, por meio da análise de freqüências e de teste para associação. Resultados: Deste contingente 73,0 por cento eram do sexo masculino, 65,0 por cento tinham idade entre 18 e 45 anos, 51,4 por cento ocupavam o setor de serviços e 25,0 por cento utilizavam meio de correção visual: Sob o ponto de vista oftalmológico, 0,5 por cento dos entrevistados não poderiam dirigir veículos automotores e 4,7 por cento só poderiam obter habilitação para condução veicular; nas categorias A e B. Mostrou-se associada à acuídade visual baixa a maior longevidade. Conclusão: Baseado nos resultados, sugere-se menor intervalo de tempo para reavaliação visual dos motoristas das categorias C, D e E.


Subject(s)
Humans , Male , Adult , Middle Aged , Automobile Driver Examination , Color Vision Defects , Color Perception/physiology , Vision Disorders/diagnosis , Vision Tests , Visual Acuity , Adolescent , Brazil , Sex Factors , Socioeconomic Factors
5.
Arq. bras. oftalmol ; 65(1): 95-98, jan.-fev. 2002. tab
Article in Portuguese | LILACS | ID: lil-308693

ABSTRACT

Objetivo: Definir as indicações mais freqüentes de ceratoplastia penetrante no Serviço de Oftalmologia da Universidade Federal do Rio Grande do Sul - a verificação da doença corneana mais transplantada bem como as médias etária e de tempo de preservação das córneas utilizadas. Métodos: Foi realizado um estudo retrospectivo comparativo entre os pacientes atendidos e que tiveram indicação de transplante de córnea (transplantados e em lista de espera) no período de janeiro de 1988 a dezembro de 1997. Resultado:As principais indicações foram: ceratocone (28,6 por cento), ceratopatia bolhosa (20,9 por cento), leucoma (12,6 por cento) e retransplante (11,0 por cento). A doença mais transplantada foi o ceratocone (95 por cento dos casos). As médias etária e de preservação das córneas utilizadas foram 44 anos e 6,6 dias respectivamen-te. Conclusão: As principais indicações de ceratoplastia penetratnte em nosso meio são o ceratocone, a ceratopatia bolhosa, os leucomas e o retransplante. A doença mais transplantada foi o ceratocone por ser a doença mais incidente e não pelo fato de termos maior oferta de córneas doadoras idosas como suspeitávamos inicialmente. Quanto às médias etária e de tempo de preservação das córneas utilizadas houve preferência estatisticamente significativa pelo uso de córneas mais jovens nos casos de ceratopatia bolhosa.


Subject(s)
Humans , Keratoplasty, Penetrating , Corneal Transplantation/methods , Brazil , Organ Preservation , Retrospective Studies , Tissue Donors
6.
Rev. bras. oftalmol ; 55(6): 21-8, jun. 1996. tab
Article in Portuguese | LILACS | ID: lil-280274

ABSTRACT

Os autores discutem o papel da tomografia computadorizada(TC) no diagnóstico de corpos estranhos intra-orbitários. O emprego da TC na avaliaçäo inicial do trauma penetrante do globo ocular e da órbita parece ser razoável.A TC tem boa sensibilidade na detecçäo de vários tipos de corpos estranhos e é, ao mesmo tempo, mais precisa do que o raio X simples (RX) na localizaçäo dos mesmos. A TC, assim como o RX, pode falhar na detecçäo de corpos estranhos de madeira ou outros materiais orgânicos assim como corpos estranhos de plástico dentro do vítreo. Para esse propósito, a ressonância magnética(RM) é um exame diagnóstico mais sensível.Contudo, a RM só pode ser realizada após descartada a possibilidade de um corpo estranho metálico, principalmente ferromagnético, pela possibilidade de movimentaçäo do mesmo durante o exame, o que poderia causar danos adicionais ao olho. Quando se sujeita de um corpo estranho intra-ocular ou intra-orbitário, com RX ou TC negativos, a RM pode ser indicada com segurança.A ecografia(ECO) é mais sensível que o RX na detecçäo de corpos estranhos intra-oculares,especialmente näo-metálicos, mas émenos sensível que a TC na detecçäo de peguenos corpos estranhos intraoculares e até mesmo grandes corpos estranhos intra-orbitários.Entretanto, a ECO pode indicar se um corpo estranhos é ferromagnético ou näo, podendo assim prever se a remoçäo do mesmo poderá ser realizada por dispositivos magnéticos.Adicionalmente, a ECO é muito útil na avaliaçäo de patologias intraoculares associadas ao trauma, como também no planejamento cirúrgico quando há hemorragia vítrea.


Subject(s)
Eye Injuries, Penetrating/diagnosis , Eye Injuries, Penetrating/therapy
7.
Arq. bras. oftalmol ; 58(6): 486-8, dez. 1995. ilus
Article in Portuguese | LILACS | ID: lil-169898

ABSTRACT

A ictiose lamelar é uma doença caracterizada por hiperceratäo da pele, ectrópio palpebral, conjuntivite e ceratite. Apresentamos um caso de úlcera corneana por exposiçäo, com infecçäo bacteriana e micótica secundária, em um paciente portador desta patologia. Säo descritas alternativas para terapêutica ocular bem como para correçäo do ectrópio


Subject(s)
Humans , Male , Adult , Ectropion/physiopathology , Ichthyosis, Lamellar/complications , Bacterial Infections/diagnosis , Keratitis/physiopathology , Corneal Ulcer/physiopathology , Ectropion/therapy , Ichthyosis, Lamellar/therapy
SELECTION OF CITATIONS
SEARCH DETAIL